Rick, Terry had informed me that Solar had trouble with this unit in making
its emissions guarantees, prior to shipping it to La Plata. I was not aware
of this when I permitted the unit.a couple of years ago. In an attempt to
solve the problem, in November, I had submitted a modification to the permit
to the state of Colorado requesting additional emissions as it appears the
unit exceeds its permitted levels during the colder months. I received a
call form the state of Colorado and they said they are hesitant to approve of
more emissions for us. We reached an agreement with the state that they
would remove the pound per hour limit and keep the ton per year requirement
in an attempt to give us more operating room (the higher emissions months
would be balanced by the warmer months which produce less emissions.
However, after Terry went through the calculations we were still exceeding
the permitted emission limits when we calculated yearly limits. I dont know
if Solar might have sold us a bill of goods but based upon emisisons
calculations, the unit cant stay under the emissions guarantees that Solar
promised. We have notified the state of Colorado, as the permit requires
and Im sure they will be following up on this. Let me know what Solar
says.......



Team San-Juan-LaPlata

01/24/2001 11:08 AM

To: Rick Smith/ET&S/Enron@Enron
cc: Larry Campbell/ET&S/Enron@Enron, Rich Jolly/ET&S/Enron@Enron

Subject: La Plata emissions issues

Rick, the A-102 unit at LaPlata is at a point, using calculated rolling
averages, that it is exceeding the tons per year emissions level of NOX, CO,
and VOC. If we continue to run at these points it could mean an NOV. The
numbers that we used on the permit are the guranteed emission numbers from
Solar Turbines (per Larry Campbell). We were wondering if you could approach
Leon O'Brien and/or Ernie Roberts on what Solar could do to remedy this
problem. We feel that a communication coming from you and Rich might carry a
little more weight then the LaPlata Gang could muster. Larry Campbell
suggested that we try to remedy this through Solar Turbines first, before we
pursue other avenues. Let us know if we can help in any
way. Tnanks, Terry