![]() |
Enron Mail |
Info related to the TA1 action item given in the RMS meeting today. Also attached is the email I originally sent to SET on August 1, 2001. Thanks, Dave Darnell =========== 602-432-3353 - X12-5v4010.pdf - ISA_IEA.doc Content-Transfer-Encoding: 7bit Reply-To: <dave.darnell@systrends.com< From: "Dave Darnell" <dave.darnell@systrends.com< To: <set@ercot.com< Cc: <tdtwg@ercot.com< Subject: ISA/IEA and GS/GE Control Segments doc - FA Reconciliation Date: Wed, 1 Aug 2001 15:50:37 -0700 Message-ID: <005901c11adc$63c77d70$a815a8c0@tecradaved< MIME-Version: 1.0 Content-Type: text/plain; charset="iso-8859-1" X-Priority: 3 (Normal) X-MSMail-Priority: Normal X-Mailer: Microsoft Outlook, Build 10.0.2627 Importance: Normal X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2600.0000 Who owns the ISA/IEA and GS/GE Control Segments doc? I have a suggestion for it... It might be helpful to have information something like this in it: The GS06 (Group Control Number) of the sender's EDI GS envelope is used in the responding 997 transaction to enable 997 reconciliation. It is returned to the sender in the 997's AK102 element. In other words, the GS06 and AK102 elements are used in reconciling outbound EDI transactions with the inbound Functional Acknowledgments (997). There is no provision in the ANSI X12.5 standard for returning an ISA number in a 997. Interchange acknowledgment and reconciliation is enabled with the responding TA1 segment: <<QUOTE FROM X12 standard<< Interchange Acknowledgment TA1 To report the status of processing a received interchange header and trailer or the non-delivery by a network provider CONTROL SEGMENT TRANSACTION SETS USED IN: None REF ELE ID ATTRIBUTES NAME 01 I12 Interchange Control Number N0 9/9 M 02 I08 Interchange Date DT 6/6 M 03 I09 Interchange Time TM 4/4 M 04 I17 Interchange Acknowledgment Code ID 1/1 M 05 I18 Interchange Note Code ID 3/3 M <<ENDQUOTE FROM X12 standard<< <<<NOTE FROM D.DARNELL<<< I could find no reference to TA1 segments in our TX SET documents.. so if there is somebody please point me to it. The TA1 segment may be worthy of future discussion in the TX SET work group. Meanwhile .... I would recommend that the GS06 (GS control number) always be unique for a trading partner/functional group. You could do this by incrementing by one every time you ran a map... and then storing the last GS06 sent for use by the map (to increment) next time around. If you ALWAYS have only one Functional Group per ISA.. then you could make the GS06 the same as the ISA control number (ISA13). COMMENTS?? Best Regards, Dave ~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Dave Darnell Systrends, Inc 7855 South River Parkway, Suite 111 Tempe, Arizona 85284 Web: www.systrends.com Phone:480.756.6777 x201, Mobile:602.432.3353,eFax:208.441.6982 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ - NY EDI TOP 1-24-01.doc
|