Enron Mail |
Hi Chris,
Any opinion on the major component question? Kay ---------------------- Forwarded by Kay Mann/Corp/Enron on 10/19/2000 03:39 PM --------------------------- Scott Dieball@ENRON_DEVELOPMENT 10/17/2000 03:44 PM To: Kathleen Clark/ENRON_DEVELOPMENT@ENRON_DEVELOPMENT cc: Kay Mann/Corp/Enron@ENRON Subject: GE LM6000/Change Order #2/PSCO Taking a quick look at the CO I am not sure what are GE's comments. Do we have a redline copy showing GE's comments? I can't remember if I made this comment previously, but are the exhaust stacks considered "major components" (or whatever the correct defined term is under the Agreement) for purposes of delay LD's? If so, then we need to revise the CO accordingly. Also, do we need the defined term "Purchase Amount Increase" in Section 3(b) in Part II? Scott Enron Engineering & Construction Company From: Kathleen Clark 10/17/2000 09:21 AM To: Scott Dieball/ENRON_DEVELOPMENT cc: Kay Mann/Corp/Enron@ENRON Subject: Change order #2, PSCO Scott: FYI Kathy ---------------------- Forwarded by Kathleen Clark/ENRON_DEVELOPMENT on 10/17/2000 09:20 AM --------------------------- To: Dale Rasmussen/HOU/ECT@ECT, Lisa Bills/Corp/Enron@ENRON, Ben Jacoby/HOU/ECT@ECT, Sheila Tweed/HOU/ECT@ECT, Chris Booth/NA/Enron@Enron, Kathleen Clark/ENRON_DEVELOPMENT@ENRON_DEVELOPMENT cc: Subject: Change order #2, PSCO Is this ok with everybody? It incorporates GE's latest comments. Kay
|