![]() |
Enron Mail |
Hello all!
As a final confirmation and reminder for Friday/Saturday's course, here are the details: When: Friday, August 24th and Saturday, August 25th Time: 8:30am start (both days), ending around 4:30 at the latest Where: 2WTC Oregon Room Directions: Take the skybridge toward building 2 and go down one level. Go through the two sets of double doors and turn left. The Oregon room is the 2nd conference room on the right (in the corner, just past Mezzanine 5). What to bring: Paper and a pen/pencil There will be breaks in the morning and afternoon, and breakfast and lunch will be served. If you have any questions, please let me know! Thanks, Grace x8321 =========================================================================== Electric System Operation for the Non-Engineer Instructor: Skip Collier, Professional Training Systems, Inc. 2WTC Mezzanine Level-Oregon Room August 24-25, 2001 Course Highlights: Generation Transmission & Overhead Distribution Systems Underground Distribution Switchgear Voltage Control Matching Generation Who should attend? It is a must for any individual that works with technical terminology of electrical engineers. Mechanical engineers, civil engineers, engineering techs, purchasing agents, contract specialists and those in public relations would find this course helpful. Overview: The two-day workshop provides the employee with a comprehensive understanding of system operations including fossil fuel, hydro and nuclear generation, transmission and distribution. The course will provide not only technical information but also economics of operation, system and equipment protection and safety. Course Schedule: The course will begin at 8:30am each day, until about 5:00pm. A light breakfast will be available for all attendees. Lunch will be provided. Course Outline: Day One 8:15am-8:30am Light breakfast/Registration 8:30am-4:30pm Generation Construction and operation of steam, hydro and gas turbine Transmission and Overhead Distribution Systems Power and distribution transformers Wye and Delta overhead distribution systems Power and energy calculations Adjourn Day Two 8:15am-8:30am Light breakfast/Registration 8:30am-4:30pm Underground Distribution Padmount transformers, underground cable, conduit and reliability overhead versus underground. Switchgear Circuit switches, fuses and cut outs Voltage Control Voltage control using non-load tap changers, load tap changers, and voltage regulators Matching Generation Automotive versus manual matching of generation to load, transmission intertie Adjourn
|